跳至主要内容

博文

90℃ dual source heat pump | Hstarschiller.com

  H.Stars Group   has recently signed a contract with 90℃ dual source heat pump unit project for one of the famous automobile factory to replace the traditional boiler. Below are the features of high-efficiency 90-degree dual source heat pump: 1. Special design and customized size for easy installation. 2. Adopt the special compressor of Hanbell high temperature heat pump, with high compression ratio, high energy efficiency, stable performance, multi-level energy adjustment, accurately matching the load change of the unit, low noise and low vibration. It has a wide operating range and can adapt to different operating conditions. 3. Environmental protection adopts environmentally friendly refrigerant: R134A. 4. It is matched with the high-efficiency heat exchanger produced by our factory and adopts the latest high-efficiency heat exchange copper tube to optimize the heat transfer efficiency, compact structure, strengthen heat transfer on the water side and the refrigerant side, reduce u

How to reduce the initial investment and operation cost of low-temperature chiller for chemical plants

  Nowadays, chemical plants always consider how to reduce the initial investment and operation cost when they need to install a  low-temperature chiller system for the factory. Because low temperature refrigeration unit is a very important equipment in chemical plant, which plays an important role in safety production. The initial investment of   low-temperature refrigeration unit   is large, and it is also one of the equipment with large energy consumption in chemical plant. How to reduce the investment and operation cost of   Glycol low temperature chiller   and system is very important for enterprises. This is one of H.Stars Group projects for one of the chemical base . The cryogenic unit and chilled water circulation system are designed and implemented .At first, the company's design engineers only chose the Ultra low temperature chiller and system design according to the cooling capacity required by customers. However, with the deepening of the project,  H.Stars Group  has fou

How to select and design with industrial low temperature chiller unit | Hstarschiller.com

  Recently, when communicating with some customers, we found that we were not very clear about the type selection and system design of low temperature units. However, the   low temperature chiller   is a very important equipment for chemical industry, raw material pharmaceutical factory and other enterprises, and it is also the place with the largest energy consumption for such enterprises. Therefore, how to select the appropriate number of industrial low temperature chiller and design a reasonable frozen water circulation system is particularly important. There is an example on  H.Stars Group  project reference.To us, the key points of  glycol chiller  design ,take the recent project of Anhui Xiangbang Chemical Co., Ltd. as an example, the total cooling capacity demand of the enterprise is 1500kW, and the outlet water temperature is required to be - 15 ℃. According to the experience, the following three points are sorted out for your reference: 1、 Selection of the number of refrigerat

Energy Saving Chiller System with Heat Recovery Unit of 70℃ Hot Water | Hstarschiller.com

  The   heat recovery chiller   is a new type of energy recovery chiller. It has one more heat recovery device than conventional chillers,it is an   economical chiller . It can produce hot water for free at the same time when making cold water. The hot water temperature can reach up to 70 degrees. It is very suitable for hotels, guesthouses and pharmaceuticals, electronic constant temperature and humidity workshops and other places that have both cold and heat requirements. Heat recovery chillers types Heat recovery chillers can be divided into two types: partial heat recovery and full heat recovery according to the amount of recovery. Partial heat recovery can recover 30% of the heat energy of the cooling capacity, while full heat recovery can recover the cooling capacity + The equivalent amount of heat energy of the input power. The main features of the heat recovery chillers: The economic benefits of heat recovery chillers are not only energy recovery, but also reducing heat polluti

Application of water chiller in concrete mixing | Industrial condenser manufacturers

  In 2004, the Ministry of Construction issued a document that chilled water must be used in the concrete mixer projects such as subways, bridges, and dams. The chilled water varies according to the outdoor temperature across the country, and the general temperature is 2℃-7℃ . H.Stars Group  has not been involved in this market before, and customers know little about chillers, so ordinary customers buy ice cubes and ordinary tap water to solve the problem according to production needs. According to relevant statistics, this market is worth more than 3 million dollars per year. At present, only a few  concrete chiller plant  pays attention to this market. Since the chilled water temperature in this market is 2℃-7℃, the chillers are generally ammonia machines. Competing with other chiller manufacturers in this market, H.Stars Group concrete water chiller can directly supply 2°C water with advantages in terms of technology, equipment, solutions, and services. As long as this market and vi

Tips for seasonal water chiller system shutdown in winter | Hstarschiller.com

  Introduction: Winter is coming, and the ambient temperature is about to drop below zero. This will cause great damage to the chillers, water pumps, cooling towers, terminals and other equipment. In order to ensure that chillers work normally during winter, the chiller has to survive in the low temperature environment, because it will cause a great loss to users if the unit is not maintained with proper seasonal shutdown. First of all, when those chillers are not going to turn on during winter for seasonal shutdown, water among chillers, pipes, pumps, cooling towers and terminals must be drained out clean in advance when the ambient temperature is below zero. How are we going to do for the water chiller HVAC system shutdown in winter ? Here are the tips below for seasonal water chiller system shutdown in winter how to drain out the water from HVAC system. 1.  Shell and Tube Condenser : Open the end cap of the water pipe.  After opening, pay attention to the end cover and screws. Insta

Compressor Selection of Intelligent Manufacturing | Hstarschiller.com

  From the perspective of design to talk about the special "intelligent" creation of H.Stars Group,which is related to compressor type selection. According to the conventional thinking, the choice of compressor type is not much difficult , small unit with scroll compressor, medium unit with screw compressor, large unit with centrifugal compressor. Why mention the compressor type choice again? Let's do a simulation selection. Suppose we need a  300KW water-cooled chiller Screw Type,40STD-280WS4,Cooling Capacity:284kW,Price is 15200USD Scroll Type,20STB-100WFO4,Cooling Capacity:300kW,Price is 13500USD From the data, the cooling capacity of the scroll type chiller is 6% larger than the  screw type chiller , and the price of the scroll type chiller is 13% lower than the screw type chiller. We believe you have a clear idea of which product is more competitive. It is also applied to  Air cooled chiller .The following introduces the scroll type chiller and screw type chiller coo