How to reduce the initial investment and operation cost of low-temperature chiller for chemical plants

 Nowadays, chemical plants always consider how to reduce the initial investment and operation cost when they need to install a  low-temperature chiller system for the factory. Because low temperature refrigeration unit is a very important equipment in chemical plant, which plays an important role in safety production. The initial investment of low-temperature refrigeration unit is large, and it is also one of the equipment with large energy consumption in chemical plant. How to reduce the investment and operation cost of Glycol low temperature chiller and system is very important for enterprises.


low-temperature chiller unit


This is one of H.Stars Group projects for one of the chemical base . The cryogenic unit and chilled water circulation system are designed and implemented .At first, the company's design engineers only chose the Ultra low temperature chiller and system design according to the cooling capacity required by customers. However, with the deepening of the project, H.Stars Group has found that the project can reduce the amount of chiller assembly by recycling the cooling capacity, so as to reduce the initial investment and operating costs.


low-temperature refrigeration unit


This is a low-temperature crystallization chemical project. The whole process is heating up first and then cooling down to obtain different chemical products. The next stage of process cooling is completed by low-temperature refrigeration unit, and then the crystalline finished solution is separated by centrifuge. The separated low-temperature solution is cooled again in the previous process (called tank B) to obtain another product. However, because the volume of tank B is limited, it is necessary to supplement low-temperature water to obtain the desired product in tank B.


Glycol low temperature chiller factory


In this process, H.Stars Group has designed an external heat exchanger to be added to fully exchange the heat between the high-temperature mixture entering the tank B and the low-temperature solution, fully absorb the cold capacity of the low-temperature solution, and then enter the tank B to crystallize to form the product, thus greatly reducing the cost of low-temperature preparation cooling capacity of chiller unit.


Through such a change, the low-temperature chiller unit needed 1800kW before, but now it only needs 1300kW, and the investment cost and operation cost have been reduced by about 25%, which has brought great value to the enterprise. At the same time, H.Stars Group also realize that it is particularly important to fully understand the production process of customers for the selection of refrigeration equipment, which not only reduces the initial investment cost, but also greatly reduces the operation cost, bringing great value to customers.

H.Stars Group has rich experience in the design and selection of low temperature chiller unit, and 28 years of professional experience has won constant praise in the field of cryogenic chemical industry.

For more details, welcome to contact us at sales@hstars.com.cn


评论

此博客中的热门博文

Avoid Downtime, Cut Costs: Smart Maintenance for Smarter Chillers

  Screw water-cooled chillers   typically operate around 3,000 hours per year, depending on China's climate and geographical conditions. Regular and scientific maintenance is crucial to ensure long-term, reliable operation, extend the lifespan, and reduce operating costs. Maintenance and Upkeep Preventive maintenance during operation and inspection involves creating annual and monthly maintenance plans based on actual operating conditions. Shutdown Procedures In winter, clean and dry the unit. Open the drain valve to empty the  shell-and-tube heat exchanger  to avoid freezing. The shutdown sequence is: chiller off - cooling tower fan off - cooling water pump off - chilled water pump off. Special attention to anti-freezing: 1. Drain the evaporator and condenser if the unit is outdoors below 0°C during standby. 2. Interlock the water flow switch with the unit to prevent freezing when the chilled water flow switch malfunctions. 3. Ensure water in the evaporator is flowi...

What are the signs of normal operation of the chiller?

  Industrial chillers  include air-cooled chillers, water-cooled chillers, and  screw chillers , which are widely used in the plastic industry, pharmaceutical industry, food processing industry, chicken hatching bases, etc. However, many customers do not know how to use the industrial chiller after purchasing it, and do not know whether the machine is working properly. Let's talk about the main signs of normal operation of the chiller. 1. Condenser: Water-cooled chiller cooling water system: The cooling water should be sufficient, the water pressure should reach more than 0.15MPa, and the temperature difference between the inlet and outlet water should not be too large, otherwise it indicates insufficient water flow. 2. Compressor: When the compressor is running, the optimal superheat is 4~8 degrees, the maximum suction superheat does not exceed 15℃, and the condensation phenomenon is limited to the compressor return air pipe, and there should be no frost in other parts. ...

What Makes High-Temperature Heat Pump Units Essential for Modern Energy Use

  High-temperature heat pump units   have become essential to modern energy utilization technologies, finding widespread applications across various industries such as industrial, agricultural, and commercial sectors. These units' unique performance and advantages are key in driving energy transitions and achieving energy conservation and emission reductions. This blog will explore the working principles, application areas, technical features, and future trends of high-temperature heat pump units. How Do High-Temperature Heat Pump Units Work? High-temperature heat pump units operate based on the principle of the reverse Carnot cycle. They use a small amount of electrical or thermal energy to absorb heat from a low-temperature source and transfer it to a high-temperature source. The process involves four key stages: evaporation, compression, condensation, and expansion. During evaporation, the refrigerant absorbs heat from the low-temperature source and turns into a low-pressur...