跳至主要内容

Energy Saving Chiller System with Heat Recovery Unit of 70℃ Hot Water | Hstarschiller.com

 The heat recovery chiller is a new type of energy recovery chiller. It has one more heat recovery device than conventional chillers,it is an economical chiller. It can produce hot water for free at the same time when making cold water. The hot water temperature can reach up to 70 degrees. It is very suitable for hotels, guesthouses and pharmaceuticals, electronic constant temperature and humidity workshops and other places that have both cold and heat requirements.


heat recovery chillers


Heat recovery chillers types
Heat recovery chillers can be divided into two types: partial heat recovery and full heat recovery according to the amount of recovery. Partial heat recovery can recover 30% of the heat energy of the cooling capacity, while full heat recovery can recover the cooling capacity + The equivalent amount of heat energy of the input power.



economical chiller


The main features of the heat recovery chillers:
The economic benefits of heat recovery chillers are not only energy recovery, but also reducing heat pollution to the environment. For example, a 1000kw heat recovery chiller, operating for 110 days a year, 12 hours a day, with a load rate of 70%, and an energy price of 1 CNY/kw.h, can save 277,200 CNY in hot water costs and reduce heat energy emissions by 277,200kw.h, which is equivalent to saving 34 tons of standard coal, 90 tons of carbon dioxide emissions.



waste heat recovery system


H.Stars Project Reference of Heat Recovery chiller

Hotel, Hunan

40STE-6720WM8B

Hot Spring Hotel

40STD-3280WM4B2

Mayor* Hotel Co., Ltd.

40STD-E1750WDB

Hong* Real Estate Development Co., Ltd.

40STD-E1630HDB

Hotel Jixi, Anhui

40STD-F1600HDB3*2

Hotel Wuzhou

40STC-1400WDBE、710WDBE

Golden * Coast City Plaza

40STD-E1280WS*3

Red Hotel

40STC-1100WDBE

Sunshine Pearl* Hot Spring Technology Development Co., Ltd.

40STD-820HSB2、1050HDB2

South* Hotel

40STE-340ASB3*2

Jing* Injection Co., Ltd.

40STD-1400WDB3

Pharmaceutical Co., Ltd.

40STC-1200WDBE

Mineral Processing Reagent Co., Ltd.

40STD-620DSLB3*2

Pharmaceutical (Hefei) Co., Ltd.

40STD-620WDBI3

Pharmaceutical Co., Ltd.

40STD-F710DSSB3、F880WSB3、F440WSB3

Li Technology Co., Ltd.

40STD-240WSB3、

40STD-790WDSLB3

Microelectronics Co., Ltd.

40STD-1210WSBI3

Semiconductor Technology Co., Ltd.

40STD-F690WSB2、180HSB2

Milk Co., Ltd.

70STE-1270WDHBE、240WDLBE、505WDHBE、

40STD-260DSLB3

mei Dairy Co., Ltd.

40STD-1160WDB3*4

40STD-E790WDB*3、790WDB2


For more above detailed project information with heat recovery system from H.Stars Group, welcome to contact us at email sales@hstars.com.cn


评论

此博客中的热门博文

Avoid Downtime, Cut Costs: Smart Maintenance for Smarter Chillers

  Screw water-cooled chillers   typically operate around 3,000 hours per year, depending on China's climate and geographical conditions. Regular and scientific maintenance is crucial to ensure long-term, reliable operation, extend the lifespan, and reduce operating costs. Maintenance and Upkeep Preventive maintenance during operation and inspection involves creating annual and monthly maintenance plans based on actual operating conditions. Shutdown Procedures In winter, clean and dry the unit. Open the drain valve to empty the  shell-and-tube heat exchanger  to avoid freezing. The shutdown sequence is: chiller off - cooling tower fan off - cooling water pump off - chilled water pump off. Special attention to anti-freezing: 1. Drain the evaporator and condenser if the unit is outdoors below 0°C during standby. 2. Interlock the water flow switch with the unit to prevent freezing when the chilled water flow switch malfunctions. 3. Ensure water in the evaporator is flowi...

What are the differences between air-cooled chillers and water-cooled chillers | Oumalchiller.com

  We all know that according to different heat dissipation methods, chillers can be divided into air-cooled chillers and water-cooled chillers. What is the difference between air-cooled chillers and water-cooled chillers? ​ 1. The  air-cooled chiller  uses copper tubes and aluminum fins to dissipate heat from the condenser. A fan is required to blow the outdoor air through the heat exchange fins and take away the heat of the condenser, so the air-cooled chiller does not need to be connected to the cooling tower. But compared with water-cooled chillers, under the same power, air-cooled chillers have larger equipment size and higher noise. The condenser of water-cooled chillers exchanges heat with the cooling water from the cooling tower through the heat exchanger. The excess waste heat will be transported to the cooling tower through the cooling water loop and released into the atmosphere, or enter the water-water heat exchanger or soil heat exchange coil for storage. Ther...

What is difference between centrifugal chiller and screw chillers?

 Water Chillers are generally divided into the following categories: screw chillers, centrifugal chillers, water ring heat pump units, plate and tube evaporative condensing screw chillers, thermal storage air conditioners, etc. Screw chiller and centrifugal chiller are equipment that we often encounter. Below,  Oumal Refrigeration  will take you to understand the difference between centrifugal chiller and screw chiller? What is a  screw chiller ? The compressor adopts a screw type, hence the name screw chiller. The refrigerant coming out of the evaporator of the unit is a gas; after adiabatic compression by the compressor, it becomes a high-temperature and high-pressure state. The compressed gas refrigerant is isobarically cooled and condensed in the condenser. After condensation, it changes into liquid refrigerant, and then expands to low pressure through the throttle valve and becomes a gas-liquid mixture. The liquid refrigerant under low temperature and low pressu...