 Air-Cooled scroll chiller VS Air-Cooled Screw Chiller

Functionally: The air-cooled screw chiller and the air-cooled scroll chiller have the same cooling function. The cooling, heating and energy are all electric energy.

Application industry: are mainly used in industry, medicine, plastic, food, coal, shopping malls and other industries.

It can be installed on the roof or outdoor courtyard, without the need for a dedicated machine room and cooling tower.

The smallest air-cooled screw chillers are 30HP/30Ton, while air-cooled scroll chillers range from 1HP/1Ton to 60HP/60Ton. The two categories differ on the basis of capacity range. Another difference is that screw chillers do not have a built-in water tank and water pump, while air-cooled scroll chillers have a water tank and water pump. Furthermore, it has a compact design, so it is easy to integrate. Unlike screw chillers with touch screens, air-cooled scroll chillers are equipped with an easy-to-use PID controller. The Oumal air-cooled screw chiller control system uses Siemens PLC + WeiView HDMI Touch Screen.


Unit characteristics comparison:

Features of air-cooled screw chiller:

Semi-hermetic screw type high-efficiency compressor, and there are single-machine system and double-machine system options. The unit has a compact structure and is easy to maintain. Adopting a new 5:6 multi-national patent asymmetric rotor tooth profile, the occlusion is tight, and the operation is stable; the use of high-efficiency motors is energy-saving and economical; the advanced intelligent defrosting method, the microcomputer analyzes the temperature of each point at any time, optimizes the defrosting cycle time, and ensures the removal of The frost is timely without affecting the heating operation, and the defrosting and heating are carried out at the same time, and the operation is more reliable and stable. Professional motor cooling device to meet harsh operating conditions. The unique design of the condensate pan eliminates the need for additional electric heating equipment, which completely eliminates the problem of freezing at the bottom of the coil during heating. A new generation of high-efficiency heat exchange tubes, the heat exchange coefficient is increased by 5%; the double-slot tube sheet hole design and advanced tube expansion technology make the structure more sealed and reliable, completely avoiding the possibility of mutual penetration. Economizer mode operation improves the cooling capacity and COP of the unit more effectively.

Air cooled screw chiller

Features of air-cooled scroll chillers:

The use of fully enclosed scroll compressors, high-efficiency and high-quality components, and optimized system design. The scroll refrigeration system is also a simple system process in the industry. The heat pump unit cancels the one-way valve and adopts the unique bidirectional expansion valve throttling technology, which makes the system process greatly simplify. That is, the system resistance is reduced, the performance is improved, and the hidden danger of leakage is reduced, and the unit runs stably and reliably. The evaporator adopts internal thread type high-efficiency heat exchange copper tube or coil evaporator. The outer surface of the copper tube is spirally smooth and the baffle plate on the water side adopts a non-short circuit design, which improves the heat exchange efficiency of chilled water mixing. The main control equipment of the unit adopts a special microcomputer controller. Parameter setting, query is convenient, and operation is simple. Unit operation, energy regulation and self-protection. Automatic monitoring, after receiving the goods, only need to connect the water system and power supply and can be used.

Air cooled scroll chiller

评论

此博客中的热门博文

Avoid Downtime, Cut Costs: Smart Maintenance for Smarter Chillers

  Screw water-cooled chillers   typically operate around 3,000 hours per year, depending on China's climate and geographical conditions. Regular and scientific maintenance is crucial to ensure long-term, reliable operation, extend the lifespan, and reduce operating costs. Maintenance and Upkeep Preventive maintenance during operation and inspection involves creating annual and monthly maintenance plans based on actual operating conditions. Shutdown Procedures In winter, clean and dry the unit. Open the drain valve to empty the  shell-and-tube heat exchanger  to avoid freezing. The shutdown sequence is: chiller off - cooling tower fan off - cooling water pump off - chilled water pump off. Special attention to anti-freezing: 1. Drain the evaporator and condenser if the unit is outdoors below 0°C during standby. 2. Interlock the water flow switch with the unit to prevent freezing when the chilled water flow switch malfunctions. 3. Ensure water in the evaporator is flowi...

How to design a water chiller system with AHU for pharmaceutical factory workshop | Hstarschiller.com

  Nowadays, it’s become more and more aware of pharmaceutical enterprises to realize the significance of building an efficient and green to environment cooling system in the factory, because it can not only help the owner to save the running cost but also contribute to the society by reducing the emissions, especially for those developed countries . But how to design a simple but energy saving cooling system with clean workshop? Below we are going to give you a real case for your reference to help you understand well, especially for those are quite new to the water chiller system field. Firstly,this project has been done by  H.Stars Group  ,including the system design,equipment manufacturing and installation etc. Below is the detailed project overview to help you understand the owner’s requirement . Project address: one of the pharmaceutical factories located in China Project desire: Requesting a constant temperature with humidity for oral solid preparation workshop Proje...

What Makes High-Temperature Heat Pump Units Essential for Modern Energy Use

  High-temperature heat pump units   have become essential to modern energy utilization technologies, finding widespread applications across various industries such as industrial, agricultural, and commercial sectors. These units' unique performance and advantages are key in driving energy transitions and achieving energy conservation and emission reductions. This blog will explore the working principles, application areas, technical features, and future trends of high-temperature heat pump units. How Do High-Temperature Heat Pump Units Work? High-temperature heat pump units operate based on the principle of the reverse Carnot cycle. They use a small amount of electrical or thermal energy to absorb heat from a low-temperature source and transfer it to a high-temperature source. The process involves four key stages: evaporation, compression, condensation, and expansion. During evaporation, the refrigerant absorbs heat from the low-temperature source and turns into a low-pressur...