 Air-Cooled scroll chiller VS Air-Cooled Screw Chiller

Functionally: The air-cooled screw chiller and the air-cooled scroll chiller have the same cooling function. The cooling, heating and energy are all electric energy.

Application industry: are mainly used in industry, medicine, plastic, food, coal, shopping malls and other industries.

It can be installed on the roof or outdoor courtyard, without the need for a dedicated machine room and cooling tower.

The smallest air-cooled screw chillers are 30HP/30Ton, while air-cooled scroll chillers range from 1HP/1Ton to 60HP/60Ton. The two categories differ on the basis of capacity range. Another difference is that screw chillers do not have a built-in water tank and water pump, while air-cooled scroll chillers have a water tank and water pump. Furthermore, it has a compact design, so it is easy to integrate. Unlike screw chillers with touch screens, air-cooled scroll chillers are equipped with an easy-to-use PID controller. The Oumal air-cooled screw chiller control system uses Siemens PLC + WeiView HDMI Touch Screen.


Unit characteristics comparison:

Features of air-cooled screw chiller:

Semi-hermetic screw type high-efficiency compressor, and there are single-machine system and double-machine system options. The unit has a compact structure and is easy to maintain. Adopting a new 5:6 multi-national patent asymmetric rotor tooth profile, the occlusion is tight, and the operation is stable; the use of high-efficiency motors is energy-saving and economical; the advanced intelligent defrosting method, the microcomputer analyzes the temperature of each point at any time, optimizes the defrosting cycle time, and ensures the removal of The frost is timely without affecting the heating operation, and the defrosting and heating are carried out at the same time, and the operation is more reliable and stable. Professional motor cooling device to meet harsh operating conditions. The unique design of the condensate pan eliminates the need for additional electric heating equipment, which completely eliminates the problem of freezing at the bottom of the coil during heating. A new generation of high-efficiency heat exchange tubes, the heat exchange coefficient is increased by 5%; the double-slot tube sheet hole design and advanced tube expansion technology make the structure more sealed and reliable, completely avoiding the possibility of mutual penetration. Economizer mode operation improves the cooling capacity and COP of the unit more effectively.

Air cooled screw chiller

Features of air-cooled scroll chillers:

The use of fully enclosed scroll compressors, high-efficiency and high-quality components, and optimized system design. The scroll refrigeration system is also a simple system process in the industry. The heat pump unit cancels the one-way valve and adopts the unique bidirectional expansion valve throttling technology, which makes the system process greatly simplify. That is, the system resistance is reduced, the performance is improved, and the hidden danger of leakage is reduced, and the unit runs stably and reliably. The evaporator adopts internal thread type high-efficiency heat exchange copper tube or coil evaporator. The outer surface of the copper tube is spirally smooth and the baffle plate on the water side adopts a non-short circuit design, which improves the heat exchange efficiency of chilled water mixing. The main control equipment of the unit adopts a special microcomputer controller. Parameter setting, query is convenient, and operation is simple. Unit operation, energy regulation and self-protection. Automatic monitoring, after receiving the goods, only need to connect the water system and power supply and can be used.

Air cooled scroll chiller

评论

此博客中的热门博文

Where are water-cooled chillers used? What is a chiller used for?

  Water-cooled chiller   is a cooling water device that can provide constant temperature, constant current and constant pressure. A chiller is a machine that achieves refrigeration through vapor compression or absorption cycles. These liquids can flow through heat exchangers to cool the air or equipment. The industrial chiller can always output ice water with a lower temperature than the ambient temperature. It can be used wherever cooling is required, either direct cooling or indirect heat exchange. The main components of a water-cooled chiller are compressor, condenser, evaporator, water pump, and water tank. Chillers have a wide range of applications. The chiller can be used to cool the injection mold, improve the quality of plastic products, cool the vacuum coating, control the temperature of the vacuum coating machine, cool the food industry, fast cooling processing, chemical industry, effectively control the temperature of chemicals, cooling buildings, concrete fast Cool...

Ways and solutions of noise produced by chillers - www.oumalchiller.com

  It is inevitable that the chiller will produce sound when it is working. For example, when the fan rotates, the fan blades rub against the air, it will produce sound. Normal sound is allowed. However, even the sophisticated refrigeration equipment will appear after a long period of use. Fault. Then, the editor of   Oumal Chiller   will take you to understand the causes and solutions of the noise produced by the chiller. First, find the reason from the parts that are easy to check and observe: 1. Are the anchor screws loose? The chiller is fixed on the ground. After running for a long time, the anchor bolts will be loose, and the chiller will be unstable, which will cause noise. This situation can be solved by replacing the anchor bolts, and vibration reduction can also be installed if conditions permit. The purpose is to make the chiller firmly fixed on the ground. 2. Whether the connecting pipeline is firm There are large and small pipes on the chiller, connecting the ...

How is the Refrigeration Industry Leading the Green Development with R404A

  As global environmental concerns continue to rise, the refrigeration industry is undergoing a significant transformation. Water-cooled low-temperature units exported overseas are now increasingly adopting the eco-friendly refrigerant R404A, leading the way in the industry's green development. Here's a deeper look into this trend. Why Is R404A Becoming the Preferred Refrigerant for  Water-Cooled Low-Temperature Units ? R404A is a blend of refrigerants that stands out due to its environmentally friendly properties. It is free from Ozone Depleting Potential (ODP) and has a relatively low Global Warming Potential (GWP), making it an ideal substitute for traditional refrigerants. This balance between high-performance cooling and environmental friendliness has made R404A especially popular in regions with strict environmental regulations, such as Europe and North America. Water-cooled low-temperature units exported to these areas are now commonly equipped with R404A to meet local ...