How to choose the type of refrigerant for the chiller | Oumalchiller.com

 The normal and safe operation of the chiller is inseparable from the refrigerant. It is the working medium that circulates in the chiller refrigeration system to achieve refrigeration. The commonly used refrigerant types for chillers are: R22, R407C, R404A, R410A, R134A, R507... Because R22 refrigerant is not environmentally friendly, most countries have now banned the use of R22. Therefore, for Omar chillers, high temperature The chiller uses R407C refrigerant, and the low-temperature chiller uses R404A. Of course, R134a, R410A, etc. can also be used according to user requirements. So, how to choose the appropriate refrigerant type for the chiller?

chiller refrigerant types

R22: Because R22 destroys the ozone layer, many countries have now banned the use of R22. Therefore, the chillers we export are generally R407C systems, unless customers require special requirements.

R407C: R407C is a mixture of R32 refrigerant and R125/refrigerant plus R134a refrigerant in a certain proportion. It is an environmentally friendly refrigerant that does not destroy the ozone layer. R407C has very similar characteristics and performance to R22, so it has become a long-term alternative to R22. At present, it is the most widely used refrigerant in the chiller system, which is environmentally friendly and economical. The chiller with R407C refrigerant is affordable.


R404A: As R404A belongs to the HFC type non-azeotropic environmentally friendly refrigerant (completely does not contain ozone-depleting CFC, HCFC), it is currently recognized and recommended by most countries in the world as a mainstream low-temperature environmentally friendly refrigerant. It is widely used in low-temperature chiller systems. middle.

R410A: It is a new environmentally friendly refrigerant that does not contain chlorine and does not destroy the ozone layer. Because the working pressure is about 1.6 times that of the ordinary R22 chiller, the cooling (warming) efficiency is high, and the material requirements for the chiller condenser and evaporator are Higher, therefore, the price of R410A chiller is higher than R22 and R407C. The new R410A refrigerant is composed of two quasi-azeotropic mixtures R32 and R125 each with 50%, mainly composed of hydrogen, fluorine and carbon elements (expressed as hfc), which is stable, non-toxic, and superior in performance. R410A was once recognized as the most suitable refrigerant to replace R22, and it has been popularized in Europe, America, Japan and other countries. R410A replaces the global trends in major international markets and prospects for its use and the dynamics of entering the international market.


R134a (is one of the most widely used medium and low temperature environmentally friendly refrigerants. It has good comprehensive performance, making it a very effective and safe alternative to R12 (dichlorodifluoromethane), which can be applied to the use of R12 refrigeration In most areas of refrigerant. Because the cooling effect of R134A is much lower than that of R22 and R407C, the cost of the R134A chiller system is much higher than that of R22/R407C under the same cooling capacity requirement.


If you don’t know how to choose the type of refrigerant for your chiller, Call us, Get your right cooling water system!


评论

此博客中的热门博文

Avoid Downtime, Cut Costs: Smart Maintenance for Smarter Chillers

  Screw water-cooled chillers   typically operate around 3,000 hours per year, depending on China's climate and geographical conditions. Regular and scientific maintenance is crucial to ensure long-term, reliable operation, extend the lifespan, and reduce operating costs. Maintenance and Upkeep Preventive maintenance during operation and inspection involves creating annual and monthly maintenance plans based on actual operating conditions. Shutdown Procedures In winter, clean and dry the unit. Open the drain valve to empty the  shell-and-tube heat exchanger  to avoid freezing. The shutdown sequence is: chiller off - cooling tower fan off - cooling water pump off - chilled water pump off. Special attention to anti-freezing: 1. Drain the evaporator and condenser if the unit is outdoors below 0°C during standby. 2. Interlock the water flow switch with the unit to prevent freezing when the chilled water flow switch malfunctions. 3. Ensure water in the evaporator is flowi...

What are the differences between air-cooled chillers and water-cooled chillers | Oumalchiller.com

  We all know that according to different heat dissipation methods, chillers can be divided into air-cooled chillers and water-cooled chillers. What is the difference between air-cooled chillers and water-cooled chillers? ​ 1. The  air-cooled chiller  uses copper tubes and aluminum fins to dissipate heat from the condenser. A fan is required to blow the outdoor air through the heat exchange fins and take away the heat of the condenser, so the air-cooled chiller does not need to be connected to the cooling tower. But compared with water-cooled chillers, under the same power, air-cooled chillers have larger equipment size and higher noise. The condenser of water-cooled chillers exchanges heat with the cooling water from the cooling tower through the heat exchanger. The excess waste heat will be transported to the cooling tower through the cooling water loop and released into the atmosphere, or enter the water-water heat exchanger or soil heat exchange coil for storage. Ther...

What is difference between centrifugal chiller and screw chillers?

 Water Chillers are generally divided into the following categories: screw chillers, centrifugal chillers, water ring heat pump units, plate and tube evaporative condensing screw chillers, thermal storage air conditioners, etc. Screw chiller and centrifugal chiller are equipment that we often encounter. Below,  Oumal Refrigeration  will take you to understand the difference between centrifugal chiller and screw chiller? What is a  screw chiller ? The compressor adopts a screw type, hence the name screw chiller. The refrigerant coming out of the evaporator of the unit is a gas; after adiabatic compression by the compressor, it becomes a high-temperature and high-pressure state. The compressed gas refrigerant is isobarically cooled and condensed in the condenser. After condensation, it changes into liquid refrigerant, and then expands to low pressure through the throttle valve and becomes a gas-liquid mixture. The liquid refrigerant under low temperature and low pressu...