How to deal with poor heat dissipation of screw chiller - Oumalchiller.com

 Industrial chillers can realize mutual switching, speed up production progress, reduce energy consumption, improve product molding efficiency, suppress product defects, and reduce the occurrence of defective products. Screw chillers are widely used in many fields such as electronics, rubber, plastics, papermaking, petroleum, chemical industry, food, machinery, brewing, vacuum coating, pharmaceuticals, etc., and are also widely used in places with centralized cooling to facilitate centralized management.


In industrial manufacturing, chillers are crucial to the transfer of heat. However, many chiller ma chines are prone to poor heat dissipation after a period of actual operation. At this time, product maintenance should be carried out in a timely manner.


First of all, let's clarify the signs of poor heat dissipation of the chiller. When the condenser of the chiller has poor heat dissipation, the efficiency of the compressor will decrease, and the operating current will increase, which will eventually lead to the air-cooled chiller high pressure. When the air-cooled high pressure rises to 24kg/cm2, the water-cooled chiller high pressure will rise to 20kg/cm2 is a sign of poor heat dissipation of the chiller. At this time, maintenance should be carried out in time.


Poor heat dissipation and treatment methods of water-cooled screw chiller:

When the heat dissipation of the condenser is poor, the efficiency of the compressor will be low, and the operating current will increase. The compressor will trip due to the protection of the high-voltage switch, causing the compressor to stop running. Whether the circulating water of the cooling tower is normal, whether the temperature of the cooling water is too high, whether the cooling tower fan pump is running, and whether the cooling water valve is open. After the above things are normal, you need to press the reset button again, or shut down and restart to operate normally. If high pressure overload occurs frequently, the condenser needs to be cleaned.



Treatment method for poor heat dissipation of air-cooled screw chiller:

1. Check whether thefin condenser of the chiller isdirty, if so, clean it with a small brush.

2. Check whether the fan of the chiller is working normally. If not, you can blow it with air or wipe it clean with a soft cloth dipped in some detergent.

3. Move the chiller to a well-ventilated place to avoid blocking the radiator.

4. If the heat dissipation performance of the chiller is still not good, you can consider upgrading the accessories of the chiller, such as fans, heat sinks or other components.



The above is Oumal's solution to the poor heat dissipation of the chiller. For more detailed information, please contact our Oumal manufacturer or Oumal sales: oumal@oumal.com.


评论

此博客中的热门博文

Avoid Downtime, Cut Costs: Smart Maintenance for Smarter Chillers

  Screw water-cooled chillers   typically operate around 3,000 hours per year, depending on China's climate and geographical conditions. Regular and scientific maintenance is crucial to ensure long-term, reliable operation, extend the lifespan, and reduce operating costs. Maintenance and Upkeep Preventive maintenance during operation and inspection involves creating annual and monthly maintenance plans based on actual operating conditions. Shutdown Procedures In winter, clean and dry the unit. Open the drain valve to empty the  shell-and-tube heat exchanger  to avoid freezing. The shutdown sequence is: chiller off - cooling tower fan off - cooling water pump off - chilled water pump off. Special attention to anti-freezing: 1. Drain the evaporator and condenser if the unit is outdoors below 0°C during standby. 2. Interlock the water flow switch with the unit to prevent freezing when the chilled water flow switch malfunctions. 3. Ensure water in the evaporator is flowi...

What Are the Key Requirements for Flooded-Type Heat Exchangers in Air Suspension Chillers

  Air suspension chillers   are crucial in many industrial and commercial applications, and the flooded-type heat exchanger is one of the most important components of these systems. Understanding the requirements of the heat exchanger is essential to ensuring the air suspension units operate efficiently and remain stable. A flooded-type heat exchanger works by transferring heat between two fluids with different temperatures. In air suspension chillers, it helps regulate temperature, optimize energy use, and improve overall performance. For instance, it can transfer heat from high-temperature gases to low-temperature liquids, or vice versa. 1. Material Requirements 1.1 Corrosion Resistance In many industrial environments, fluids can be corrosive. For example, they may come into contact with acidic or alkaline substances. To withstand these conditions, the heat exchanger’s tubes and casing need to be made from corrosion-resistant materials, such as stainless steel. Stainless ste...

Hotels Go Green: Heat Recovery Chillers Cut Costs and Carbon Footprints

  In the operation of hotels, energy costs are a significant factor that cannot be overlooked. The advent of   heat recovery chillers   offers an efficient and energy-saving solution for hotels. ​ A heat recovery chiller, in simple terms, not only performs cooling tasks but also effectively recovers heat. For hotels, this is a highly practical feature. Traditional chillers only accomplish cooling, wasting the heat generated. However, heat recovery chillers are different; they can convert the otherwise wasted heat into usable hot water. In principle, during the cooling cycle of a chiller, the refrigerant releases heat. Heat recovery chillers use special devices to collect this heat, and through a series of heat exchange processes, they can produce hot water. This hot water can be used in various scenarios within the hotel. For example, it can supply water for guest rooms' washing and brushing, provide hot water for the hotel's restaurant kitchen, and even be used for heati...