How to deal with poor heat dissipation of screw chiller - Oumalchiller.com

 Industrial chillers can realize mutual switching, speed up production progress, reduce energy consumption, improve product molding efficiency, suppress product defects, and reduce the occurrence of defective products. Screw chillers are widely used in many fields such as electronics, rubber, plastics, papermaking, petroleum, chemical industry, food, machinery, brewing, vacuum coating, pharmaceuticals, etc., and are also widely used in places with centralized cooling to facilitate centralized management.


In industrial manufacturing, chillers are crucial to the transfer of heat. However, many chiller ma chines are prone to poor heat dissipation after a period of actual operation. At this time, product maintenance should be carried out in a timely manner.


First of all, let's clarify the signs of poor heat dissipation of the chiller. When the condenser of the chiller has poor heat dissipation, the efficiency of the compressor will decrease, and the operating current will increase, which will eventually lead to the air-cooled chiller high pressure. When the air-cooled high pressure rises to 24kg/cm2, the water-cooled chiller high pressure will rise to 20kg/cm2 is a sign of poor heat dissipation of the chiller. At this time, maintenance should be carried out in time.


Poor heat dissipation and treatment methods of water-cooled screw chiller:

When the heat dissipation of the condenser is poor, the efficiency of the compressor will be low, and the operating current will increase. The compressor will trip due to the protection of the high-voltage switch, causing the compressor to stop running. Whether the circulating water of the cooling tower is normal, whether the temperature of the cooling water is too high, whether the cooling tower fan pump is running, and whether the cooling water valve is open. After the above things are normal, you need to press the reset button again, or shut down and restart to operate normally. If high pressure overload occurs frequently, the condenser needs to be cleaned.



Treatment method for poor heat dissipation of air-cooled screw chiller:

1. Check whether thefin condenser of the chiller isdirty, if so, clean it with a small brush.

2. Check whether the fan of the chiller is working normally. If not, you can blow it with air or wipe it clean with a soft cloth dipped in some detergent.

3. Move the chiller to a well-ventilated place to avoid blocking the radiator.

4. If the heat dissipation performance of the chiller is still not good, you can consider upgrading the accessories of the chiller, such as fans, heat sinks or other components.



The above is Oumal's solution to the poor heat dissipation of the chiller. For more detailed information, please contact our Oumal manufacturer or Oumal sales: oumal@oumal.com.


评论

此博客中的热门博文

Where are water-cooled chillers used? What is a chiller used for?

  Water-cooled chiller   is a cooling water device that can provide constant temperature, constant current and constant pressure. A chiller is a machine that achieves refrigeration through vapor compression or absorption cycles. These liquids can flow through heat exchangers to cool the air or equipment. The industrial chiller can always output ice water with a lower temperature than the ambient temperature. It can be used wherever cooling is required, either direct cooling or indirect heat exchange. The main components of a water-cooled chiller are compressor, condenser, evaporator, water pump, and water tank. Chillers have a wide range of applications. The chiller can be used to cool the injection mold, improve the quality of plastic products, cool the vacuum coating, control the temperature of the vacuum coating machine, cool the food industry, fast cooling processing, chemical industry, effectively control the temperature of chemicals, cooling buildings, concrete fast Cool...

Ways and solutions of noise produced by chillers - www.oumalchiller.com

  It is inevitable that the chiller will produce sound when it is working. For example, when the fan rotates, the fan blades rub against the air, it will produce sound. Normal sound is allowed. However, even the sophisticated refrigeration equipment will appear after a long period of use. Fault. Then, the editor of   Oumal Chiller   will take you to understand the causes and solutions of the noise produced by the chiller. First, find the reason from the parts that are easy to check and observe: 1. Are the anchor screws loose? The chiller is fixed on the ground. After running for a long time, the anchor bolts will be loose, and the chiller will be unstable, which will cause noise. This situation can be solved by replacing the anchor bolts, and vibration reduction can also be installed if conditions permit. The purpose is to make the chiller firmly fixed on the ground. 2. Whether the connecting pipeline is firm There are large and small pipes on the chiller, connecting the ...

How is the Refrigeration Industry Leading the Green Development with R404A

  As global environmental concerns continue to rise, the refrigeration industry is undergoing a significant transformation. Water-cooled low-temperature units exported overseas are now increasingly adopting the eco-friendly refrigerant R404A, leading the way in the industry's green development. Here's a deeper look into this trend. Why Is R404A Becoming the Preferred Refrigerant for  Water-Cooled Low-Temperature Units ? R404A is a blend of refrigerants that stands out due to its environmentally friendly properties. It is free from Ozone Depleting Potential (ODP) and has a relatively low Global Warming Potential (GWP), making it an ideal substitute for traditional refrigerants. This balance between high-performance cooling and environmental friendliness has made R404A especially popular in regions with strict environmental regulations, such as Europe and North America. Water-cooled low-temperature units exported to these areas are now commonly equipped with R404A to meet local ...