How to solve common problems of industrial chillers - Hstarschiller.com

 Industrial chillers are assembled from multiple machines and equipment such as condensers, evaporators, compressors, etc. The water chiller is widely used in plastics, electroplating, electronics, chemicals, pharmaceuticals, printing, food processing and other industrial refrigeration processes that require the use of chilled water In this field, the normal operation of the chiller is essential for daily maintenance, so what are the common problems of the chiller? Next, the H.stars will answer for you.


1. Insufficient refrigerant
Solution: The refrigerant needs to be supplemented until a sufficient amount, and the pressure is maintained at about 0.5MPa during refrigeration.
2. Due to climate reasons, the outdoor temperature is too high in summer, which causes the condensation pressure and temperature of the outdoor unit to be too high.
Solution: It is necessary to improve the working environment of the outdoor unit of industrial water chiller, and restart the machine after the temperature is suitable

industrial water chiller


3. The dust on the surface of the condenser is not cleaned for a long time, and the dust is too thick, resulting in poor heat dissipation effect, resulting in an increase in the exhaust pressure and exhaust temperature of the compressor, and a decrease in the cooling capacity.
Solution: It is necessary to remove the dust on the surface of the condenser, and it should also be cleaned regularly.
4. Excessive refrigerant was added, causing the compressor discharge pressure and temperature to be too high.
Solution: release excess refrigerant to keep the pressure at about 0.5MPa during refrigeration.
5. There is a leak in the refrigerant line.
Solution: Use a leak detector to find out where the refrigerant leaks, and then replenish the refrigerant after repairing, so that the operating pressure during refrigeration is maintained at about 0.5MPa.
6. The air filter of the indoor unit is clogged.
Solution: Clean the air filter.


heat exchanger for Water chiller


For more details, welcome to contact us at sales@hstars.com.cn

评论

此博客中的热门博文

Constant Temperature Swimming Pool Heat Pump Unit | Hstarschiller.com

  We all know that winter swimming has many advantages: 1. It can enhance cardiovascular function. 2. The stimulation of cold water can close the peripheral blood vessels, increase the blood supply of important organs such as heart, brain, liver and spleen, so that more oxygen can be delivered to brain cells in time, which is conducive to the elimination of nervous system fatigue. 3. The skin of those who insist on winter swimming is ruddy, shiny and elastic. And people also hope to enjoy the fun of swimming in winter, but not everyone can bear it.  Hstars group constant temperature swimming pool heat pump  can be a good solution. 1. Demand analysis of swimming pool with constant temperature Constant temperature swimming pool, also known as indoor constant temperature swimming pool; that is, the temperature of the water in the pool heating system is maintained at 26~28℃, which is suitable for the temperature of the human body. When the indoor swimming pool is designed, the water body o

The Role and Characteristics of Condenser in Refrigeration System

  The four major components of the refrigeration system are compressor, evaporator, condenser and throttling device. The role of the condenser in the refrigeration system is mainly to cool and liquefy the gaseous refrigerant in the high temperature and high pressure state discharged from the compressor, so as to meet the requirements of the circulating use of the refrigerant in the system. The selection of the temperature difference between the condensing temperature and the coolant inlet and outlet involves economic issues in the refrigeration system. Increasing the condensation temperature and reducing the temperature difference between the coolant inlet and outlet can increase the heat transfer temperature difference, reduce the required heat transfer area, and reduce the investment cost of heat exchange equipment. However, lowering the condensing temperature can reduce the power consumption of the refrigeration compressor. The greater the temperature difference between the coolant

How to build a cost-saving cold room for Peanut Storage

  Peanut storage conditions have significant effects on overall quality. With   H.Stars   standards for roof pitch, ventilation and other building standards, farmer stock peanut warehouses or cold room are the best solution. Here are some suggestions on one of the type peanut cold storage. Description of Peanut Cold Storage 1. Project details: The specific parameters of the Peanut Cold Storage are as follows: a. Cold storage size: 30m (length) × 25m (width) × 4.5m (height) b. Cold storage temperature: 10 ℃ c. Cold storage goods: peanuts without shell d: Storage capacity of cold storage: 1000Ton 2. After calculation, the chiller capacity of the cold storage is: 150kw 3. Refrigeration system description (1). This project adopts:  efficient refrigeration chilled water system . a. The main refrigeration equipment of the high-efficiency chilled liquid refrigeration system is the water cooled chiller unit. After commissioning and testing in the factory, the whole chilled can be shipped to cu