 Industrial chillers are assembled from multiple machines and equipment such as condensers, evaporators, compressors, etc. The water chiller is widely used in plastics, electroplating, electronics, chemicals, pharmaceuticals, printing, food processing and other industrial refrigeration processes that require the use of chilled water In this field, the normal operation of the chiller is essential for daily maintenance, so what are the common problems of the chiller? Next, the H.stars will answer for you.


1. Insufficient refrigerant
Solution: The refrigerant needs to be supplemented until a sufficient amount, and the pressure is maintained at about 0.5MPa during refrigeration.
2. Due to climate reasons, the outdoor temperature is too high in summer, which causes the condensation pressure and temperature of the outdoor unit to be too high.
Solution: It is necessary to improve the working environment of the outdoor unit of industrial water chiller, and restart the machine after the temperature is suitable

industrial water chiller


3. The dust on the surface of the condenser is not cleaned for a long time, and the dust is too thick, resulting in poor heat dissipation effect, resulting in an increase in the exhaust pressure and exhaust temperature of the compressor, and a decrease in the cooling capacity.
Solution: It is necessary to remove the dust on the surface of the condenser, and it should also be cleaned regularly.
4. Excessive refrigerant was added, causing the compressor discharge pressure and temperature to be too high.
Solution: release excess refrigerant to keep the pressure at about 0.5MPa during refrigeration.
5. There is a leak in the refrigerant line.
Solution: Use a leak detector to find out where the refrigerant leaks, and then replenish the refrigerant after repairing, so that the operating pressure during refrigeration is maintained at about 0.5MPa.
6. The air filter of the indoor unit is clogged.
Solution: Clean the air filter.


heat exchanger for Water chiller


For more details, welcome to contact us at sales@hstars.com.cn

评论

此博客中的热门博文

Avoid Downtime, Cut Costs: Smart Maintenance for Smarter Chillers

  Screw water-cooled chillers   typically operate around 3,000 hours per year, depending on China's climate and geographical conditions. Regular and scientific maintenance is crucial to ensure long-term, reliable operation, extend the lifespan, and reduce operating costs. Maintenance and Upkeep Preventive maintenance during operation and inspection involves creating annual and monthly maintenance plans based on actual operating conditions. Shutdown Procedures In winter, clean and dry the unit. Open the drain valve to empty the  shell-and-tube heat exchanger  to avoid freezing. The shutdown sequence is: chiller off - cooling tower fan off - cooling water pump off - chilled water pump off. Special attention to anti-freezing: 1. Drain the evaporator and condenser if the unit is outdoors below 0°C during standby. 2. Interlock the water flow switch with the unit to prevent freezing when the chilled water flow switch malfunctions. 3. Ensure water in the evaporator is flowi...

How to design a water chiller system with AHU for pharmaceutical factory workshop | Hstarschiller.com

  Nowadays, it’s become more and more aware of pharmaceutical enterprises to realize the significance of building an efficient and green to environment cooling system in the factory, because it can not only help the owner to save the running cost but also contribute to the society by reducing the emissions, especially for those developed countries . But how to design a simple but energy saving cooling system with clean workshop? Below we are going to give you a real case for your reference to help you understand well, especially for those are quite new to the water chiller system field. Firstly,this project has been done by  H.Stars Group  ,including the system design,equipment manufacturing and installation etc. Below is the detailed project overview to help you understand the owner’s requirement . Project address: one of the pharmaceutical factories located in China Project desire: Requesting a constant temperature with humidity for oral solid preparation workshop Proje...

What Are the Key Requirements for Flooded-Type Heat Exchangers in Air Suspension Chillers

  Air suspension chillers   are crucial in many industrial and commercial applications, and the flooded-type heat exchanger is one of the most important components of these systems. Understanding the requirements of the heat exchanger is essential to ensuring the air suspension units operate efficiently and remain stable. A flooded-type heat exchanger works by transferring heat between two fluids with different temperatures. In air suspension chillers, it helps regulate temperature, optimize energy use, and improve overall performance. For instance, it can transfer heat from high-temperature gases to low-temperature liquids, or vice versa. 1. Material Requirements 1.1 Corrosion Resistance In many industrial environments, fluids can be corrosive. For example, they may come into contact with acidic or alkaline substances. To withstand these conditions, the heat exchanger’s tubes and casing need to be made from corrosion-resistant materials, such as stainless steel. Stainless ste...