How to solve common problems of industrial chillers - Hstarschiller.com

 Industrial chillers are assembled from multiple machines and equipment such as condensers, evaporators, compressors, etc. The water chiller is widely used in plastics, electroplating, electronics, chemicals, pharmaceuticals, printing, food processing and other industrial refrigeration processes that require the use of chilled water In this field, the normal operation of the chiller is essential for daily maintenance, so what are the common problems of the chiller? Next, the H.stars will answer for you.


1. Insufficient refrigerant
Solution: The refrigerant needs to be supplemented until a sufficient amount, and the pressure is maintained at about 0.5MPa during refrigeration.
2. Due to climate reasons, the outdoor temperature is too high in summer, which causes the condensation pressure and temperature of the outdoor unit to be too high.
Solution: It is necessary to improve the working environment of the outdoor unit of industrial water chiller, and restart the machine after the temperature is suitable

industrial water chiller


3. The dust on the surface of the condenser is not cleaned for a long time, and the dust is too thick, resulting in poor heat dissipation effect, resulting in an increase in the exhaust pressure and exhaust temperature of the compressor, and a decrease in the cooling capacity.
Solution: It is necessary to remove the dust on the surface of the condenser, and it should also be cleaned regularly.
4. Excessive refrigerant was added, causing the compressor discharge pressure and temperature to be too high.
Solution: release excess refrigerant to keep the pressure at about 0.5MPa during refrigeration.
5. There is a leak in the refrigerant line.
Solution: Use a leak detector to find out where the refrigerant leaks, and then replenish the refrigerant after repairing, so that the operating pressure during refrigeration is maintained at about 0.5MPa.
6. The air filter of the indoor unit is clogged.
Solution: Clean the air filter.


heat exchanger for Water chiller


For more details, welcome to contact us at sales@hstars.com.cn

评论

此博客中的热门博文

Avoid Downtime, Cut Costs: Smart Maintenance for Smarter Chillers

  Screw water-cooled chillers   typically operate around 3,000 hours per year, depending on China's climate and geographical conditions. Regular and scientific maintenance is crucial to ensure long-term, reliable operation, extend the lifespan, and reduce operating costs. Maintenance and Upkeep Preventive maintenance during operation and inspection involves creating annual and monthly maintenance plans based on actual operating conditions. Shutdown Procedures In winter, clean and dry the unit. Open the drain valve to empty the  shell-and-tube heat exchanger  to avoid freezing. The shutdown sequence is: chiller off - cooling tower fan off - cooling water pump off - chilled water pump off. Special attention to anti-freezing: 1. Drain the evaporator and condenser if the unit is outdoors below 0°C during standby. 2. Interlock the water flow switch with the unit to prevent freezing when the chilled water flow switch malfunctions. 3. Ensure water in the evaporator is flowi...

Hotels Go Green: Heat Recovery Chillers Cut Costs and Carbon Footprints

  In the operation of hotels, energy costs are a significant factor that cannot be overlooked. The advent of   heat recovery chillers   offers an efficient and energy-saving solution for hotels. ​ A heat recovery chiller, in simple terms, not only performs cooling tasks but also effectively recovers heat. For hotels, this is a highly practical feature. Traditional chillers only accomplish cooling, wasting the heat generated. However, heat recovery chillers are different; they can convert the otherwise wasted heat into usable hot water. In principle, during the cooling cycle of a chiller, the refrigerant releases heat. Heat recovery chillers use special devices to collect this heat, and through a series of heat exchange processes, they can produce hot water. This hot water can be used in various scenarios within the hotel. For example, it can supply water for guest rooms' washing and brushing, provide hot water for the hotel's restaurant kitchen, and even be used for heati...

What Are the Key Requirements for Flooded-Type Heat Exchangers in Air Suspension Chillers

  Air suspension chillers   are crucial in many industrial and commercial applications, and the flooded-type heat exchanger is one of the most important components of these systems. Understanding the requirements of the heat exchanger is essential to ensuring the air suspension units operate efficiently and remain stable. A flooded-type heat exchanger works by transferring heat between two fluids with different temperatures. In air suspension chillers, it helps regulate temperature, optimize energy use, and improve overall performance. For instance, it can transfer heat from high-temperature gases to low-temperature liquids, or vice versa. 1. Material Requirements 1.1 Corrosion Resistance In many industrial environments, fluids can be corrosive. For example, they may come into contact with acidic or alkaline substances. To withstand these conditions, the heat exchanger’s tubes and casing need to be made from corrosion-resistant materials, such as stainless steel. Stainless ste...