 Industrial chillers are assembled from multiple machines and equipment such as condensers, evaporators, compressors, etc. The water chiller is widely used in plastics, electroplating, electronics, chemicals, pharmaceuticals, printing, food processing and other industrial refrigeration processes that require the use of chilled water In this field, the normal operation of the chiller is essential for daily maintenance, so what are the common problems of the chiller? Next, the H.stars will answer for you.


1. Insufficient refrigerant
Solution: The refrigerant needs to be supplemented until a sufficient amount, and the pressure is maintained at about 0.5MPa during refrigeration.
2. Due to climate reasons, the outdoor temperature is too high in summer, which causes the condensation pressure and temperature of the outdoor unit to be too high.
Solution: It is necessary to improve the working environment of the outdoor unit of industrial water chiller, and restart the machine after the temperature is suitable

industrial water chiller


3. The dust on the surface of the condenser is not cleaned for a long time, and the dust is too thick, resulting in poor heat dissipation effect, resulting in an increase in the exhaust pressure and exhaust temperature of the compressor, and a decrease in the cooling capacity.
Solution: It is necessary to remove the dust on the surface of the condenser, and it should also be cleaned regularly.
4. Excessive refrigerant was added, causing the compressor discharge pressure and temperature to be too high.
Solution: release excess refrigerant to keep the pressure at about 0.5MPa during refrigeration.
5. There is a leak in the refrigerant line.
Solution: Use a leak detector to find out where the refrigerant leaks, and then replenish the refrigerant after repairing, so that the operating pressure during refrigeration is maintained at about 0.5MPa.
6. The air filter of the indoor unit is clogged.
Solution: Clean the air filter.


heat exchanger for Water chiller


For more details, welcome to contact us at sales@hstars.com.cn

评论

此博客中的热门博文

Avoid Downtime, Cut Costs: Smart Maintenance for Smarter Chillers

  Screw water-cooled chillers   typically operate around 3,000 hours per year, depending on China's climate and geographical conditions. Regular and scientific maintenance is crucial to ensure long-term, reliable operation, extend the lifespan, and reduce operating costs. Maintenance and Upkeep Preventive maintenance during operation and inspection involves creating annual and monthly maintenance plans based on actual operating conditions. Shutdown Procedures In winter, clean and dry the unit. Open the drain valve to empty the  shell-and-tube heat exchanger  to avoid freezing. The shutdown sequence is: chiller off - cooling tower fan off - cooling water pump off - chilled water pump off. Special attention to anti-freezing: 1. Drain the evaporator and condenser if the unit is outdoors below 0°C during standby. 2. Interlock the water flow switch with the unit to prevent freezing when the chilled water flow switch malfunctions. 3. Ensure water in the evaporator is flowi...

What are the differences between air-cooled chillers and water-cooled chillers | Oumalchiller.com

  We all know that according to different heat dissipation methods, chillers can be divided into air-cooled chillers and water-cooled chillers. What is the difference between air-cooled chillers and water-cooled chillers? ​ 1. The  air-cooled chiller  uses copper tubes and aluminum fins to dissipate heat from the condenser. A fan is required to blow the outdoor air through the heat exchange fins and take away the heat of the condenser, so the air-cooled chiller does not need to be connected to the cooling tower. But compared with water-cooled chillers, under the same power, air-cooled chillers have larger equipment size and higher noise. The condenser of water-cooled chillers exchanges heat with the cooling water from the cooling tower through the heat exchanger. The excess waste heat will be transported to the cooling tower through the cooling water loop and released into the atmosphere, or enter the water-water heat exchanger or soil heat exchange coil for storage. Ther...

What is difference between centrifugal chiller and screw chillers?

 Water Chillers are generally divided into the following categories: screw chillers, centrifugal chillers, water ring heat pump units, plate and tube evaporative condensing screw chillers, thermal storage air conditioners, etc. Screw chiller and centrifugal chiller are equipment that we often encounter. Below,  Oumal Refrigeration  will take you to understand the difference between centrifugal chiller and screw chiller? What is a  screw chiller ? The compressor adopts a screw type, hence the name screw chiller. The refrigerant coming out of the evaporator of the unit is a gas; after adiabatic compression by the compressor, it becomes a high-temperature and high-pressure state. The compressed gas refrigerant is isobarically cooled and condensed in the condenser. After condensation, it changes into liquid refrigerant, and then expands to low pressure through the throttle valve and becomes a gas-liquid mixture. The liquid refrigerant under low temperature and low pressu...