 Although most of the various industrial chillers produced in my country are imported compressors, which have a long service life, but in actual use, if the user does not carefully maintain and maintain the compressors of the industrial chillers, Different degrees of failures will also occur, seriously affecting the performance of the entire industrial chiller. There are several effective measures to prevent industrial chiller compressors from malfunctioning, including:


Regular maintenance: Regular maintenance of the compressor, including cleaning and replacing parts, can prevent malfunctioning due to wear and tear.During the use of industrial chillers, it is necessary to pay attention to the noise of the compressor at all times. If the noise increases significantly, according to the experience introduced by the industrial cooler factory, it is necessary to complete the shutdown inspection in a timely and effective manner at this time to ensure normal operation. On the basis of this, complete the maintenance work of industrial cooler compressors. Note: Once the compressor makes noise, you must be more vigilant, often small problems will cause complex and serious failures in the later stage, such as compressor liquid shock.

Measure the operating temperature: During the operation of the industrial chiller, it is necessary to measure the specific operating temperature of the compressor of the industrial chiller by hand or equipment at any time. If the temperature is too high, it means that the industrial chiller is in an overloaded state. At this time, it is necessary to measure the current and voltage. In order to achieve the purpose of fault detection, so as to ensure that the industrial chiller compressor is in an absolutely safe operating state, reach a suitable operating temperature, and complete the entire operating process. Note: If the temperature of the compressor is too high, it may also be caused by too little fluorine, too small compressor power, too long capillary, poor condensation effect, temperature control failure, and lack of oil in the compressor. The damage is very serious, so special attention must be paid.


Clean condenser coils: The condenser coils of the chiller should be kept clean to ensure that the compressor is not overworked due to reduced heat transfer.Pay attention to the pressure gauge,if the high pressure gauge is very high, please check the condenser coil and clean it when necessary.


Proper refrigerant charge: The compressor should have the correct refrigerant charge to ensure that it is not working harder than necessary, which can cause it to malfunction.


Monitoring of operating conditions: The operating conditions of the compressor, including temperature and pressure, should be monitored to ensure that it is not overworked or subjected to conditions that can cause malfunctioning.


Training of personnel: Proper training of personnel in charge of operating and maintaining the compressor can prevent mistakes that can cause the compressor to damage.

评论

此博客中的热门博文

Avoid Downtime, Cut Costs: Smart Maintenance for Smarter Chillers

  Screw water-cooled chillers   typically operate around 3,000 hours per year, depending on China's climate and geographical conditions. Regular and scientific maintenance is crucial to ensure long-term, reliable operation, extend the lifespan, and reduce operating costs. Maintenance and Upkeep Preventive maintenance during operation and inspection involves creating annual and monthly maintenance plans based on actual operating conditions. Shutdown Procedures In winter, clean and dry the unit. Open the drain valve to empty the  shell-and-tube heat exchanger  to avoid freezing. The shutdown sequence is: chiller off - cooling tower fan off - cooling water pump off - chilled water pump off. Special attention to anti-freezing: 1. Drain the evaporator and condenser if the unit is outdoors below 0°C during standby. 2. Interlock the water flow switch with the unit to prevent freezing when the chilled water flow switch malfunctions. 3. Ensure water in the evaporator is flowi...

What are the differences between air-cooled chillers and water-cooled chillers | Oumalchiller.com

  We all know that according to different heat dissipation methods, chillers can be divided into air-cooled chillers and water-cooled chillers. What is the difference between air-cooled chillers and water-cooled chillers? ​ 1. The  air-cooled chiller  uses copper tubes and aluminum fins to dissipate heat from the condenser. A fan is required to blow the outdoor air through the heat exchange fins and take away the heat of the condenser, so the air-cooled chiller does not need to be connected to the cooling tower. But compared with water-cooled chillers, under the same power, air-cooled chillers have larger equipment size and higher noise. The condenser of water-cooled chillers exchanges heat with the cooling water from the cooling tower through the heat exchanger. The excess waste heat will be transported to the cooling tower through the cooling water loop and released into the atmosphere, or enter the water-water heat exchanger or soil heat exchange coil for storage. Ther...

What is difference between centrifugal chiller and screw chillers?

 Water Chillers are generally divided into the following categories: screw chillers, centrifugal chillers, water ring heat pump units, plate and tube evaporative condensing screw chillers, thermal storage air conditioners, etc. Screw chiller and centrifugal chiller are equipment that we often encounter. Below,  Oumal Refrigeration  will take you to understand the difference between centrifugal chiller and screw chiller? What is a  screw chiller ? The compressor adopts a screw type, hence the name screw chiller. The refrigerant coming out of the evaporator of the unit is a gas; after adiabatic compression by the compressor, it becomes a high-temperature and high-pressure state. The compressed gas refrigerant is isobarically cooled and condensed in the condenser. After condensation, it changes into liquid refrigerant, and then expands to low pressure through the throttle valve and becomes a gas-liquid mixture. The liquid refrigerant under low temperature and low pressu...