 Industrial Chillers are widely used, providing cooling water systems for industrial production and helping companies improve product output and quality. Therefore, we need to understand how to use chillers simply and correctly to avoid problems during use and delay production. Let us briefly understand the use of chillers from the following aspects.


One: the protection of the chiller:

1. Check whether the voltage is normal, lack of phase,

2. Check and record the running current.

3. Measure and record whether the high and low pressure and temperature control temperature are normal.

4. Under normal conditions, the high pressure is 1.5MPa / the low pressure is 0.45MPa4 Check whether the interlocking control circuit device is loose and aging.

5. Check whether the oil level and oil temperature are normal.

6. Check the compressor for abnormal sound and abnormal vibration.

7. Refrigerant system test.

8. Overall commissioning and testing.

9. Regularly check whether the quality of the chilled water and cooling water is normal. When the water quality of the water source becomes dirty or degenerated, please replace the water source in time.


Two: The annual maintenance of the chiller is as follows:

1. Clean the condenser (every six months of cumulative operation)

2. Cleaning the cooling tower (the water-cooled chiller should be cleaned once every three months after accumulative operation)

3. Check the refrigeration oil and lubricating oil system, and replace and supplement the industrial chiller if necessary.

4. Check the circuit system of the water chiller system.

5. Compressor motor coil insulation test for industrial chillers.

6. Check whether the filter drier is normal or not, and replace it if necessary.


Three: the precise use of chillers knowledge:

7. Check the amount of refrigerant and replenish refrigerant in time.

8. Check and correct the high and low pressure switches.

9. Check and calibrate the thermostat.

10. Test run and general calibration, test whether the superheat is normal and whether there is abnormal sound of each component.


Generally, water cooling (that is, natural water and water tower cooling methods) cannot achieve high precision and high efficiency.

screw air chiller


The purpose of temperature control, because natural water and cooling tower heat dissipation are inevitably affected by natural air temperature, the water temperature in winter is low in summer, and the water temperature is high in summer. If the air temperature is 30°C, it is almost impossible for the water temperature to reach 10°C, so it is extremely unstable to control in this way. The water chiller is completely different from the general water cooling equipment, because the chiller has a completely independent refrigeration system, which will never be affected by the temperature and the environment. The purpose of high-efficiency temperature control. The chiller is equipped with an independent water circulation system, and the water in the chiller is recycled, which can save a lot of water. Therefore, industrial production is inseparable from industrial chillers. Oumal specializes in the production of industrial chillers to help companies provide industrial chilled water system solutions. Contact us if you are looking for a solution for your industrial chilled water system.


评论

此博客中的热门博文

Where are water-cooled chillers used? What is a chiller used for?

  Water-cooled chiller   is a cooling water device that can provide constant temperature, constant current and constant pressure. A chiller is a machine that achieves refrigeration through vapor compression or absorption cycles. These liquids can flow through heat exchangers to cool the air or equipment. The industrial chiller can always output ice water with a lower temperature than the ambient temperature. It can be used wherever cooling is required, either direct cooling or indirect heat exchange. The main components of a water-cooled chiller are compressor, condenser, evaporator, water pump, and water tank. Chillers have a wide range of applications. The chiller can be used to cool the injection mold, improve the quality of plastic products, cool the vacuum coating, control the temperature of the vacuum coating machine, cool the food industry, fast cooling processing, chemical industry, effectively control the temperature of chemicals, cooling buildings, concrete fast Cool...

Ways and solutions of noise produced by chillers - www.oumalchiller.com

  It is inevitable that the chiller will produce sound when it is working. For example, when the fan rotates, the fan blades rub against the air, it will produce sound. Normal sound is allowed. However, even the sophisticated refrigeration equipment will appear after a long period of use. Fault. Then, the editor of   Oumal Chiller   will take you to understand the causes and solutions of the noise produced by the chiller. First, find the reason from the parts that are easy to check and observe: 1. Are the anchor screws loose? The chiller is fixed on the ground. After running for a long time, the anchor bolts will be loose, and the chiller will be unstable, which will cause noise. This situation can be solved by replacing the anchor bolts, and vibration reduction can also be installed if conditions permit. The purpose is to make the chiller firmly fixed on the ground. 2. Whether the connecting pipeline is firm There are large and small pipes on the chiller, connecting the ...

How is the Refrigeration Industry Leading the Green Development with R404A

  As global environmental concerns continue to rise, the refrigeration industry is undergoing a significant transformation. Water-cooled low-temperature units exported overseas are now increasingly adopting the eco-friendly refrigerant R404A, leading the way in the industry's green development. Here's a deeper look into this trend. Why Is R404A Becoming the Preferred Refrigerant for  Water-Cooled Low-Temperature Units ? R404A is a blend of refrigerants that stands out due to its environmentally friendly properties. It is free from Ozone Depleting Potential (ODP) and has a relatively low Global Warming Potential (GWP), making it an ideal substitute for traditional refrigerants. This balance between high-performance cooling and environmental friendliness has made R404A especially popular in regions with strict environmental regulations, such as Europe and North America. Water-cooled low-temperature units exported to these areas are now commonly equipped with R404A to meet local ...