 Air-cooled chillers, as a kind of more efficient refrigeration equipment in chiller products, are widely used in the domestic industrial market and become necessary equipment for many industrial production.


chiller product



At the same time, although the air-cooled chiller is equipped with multiple protection devices, these are all to prevent the failure from directly damaging the unit. If the company wants to ensure that the air-cooled chiller has high cooling efficiency and long service life, it must remember to do regular maintenance. So, how should the normal safety maintenance and testing of air-cooled chillers be carried out?


1) Check the stability of voltage and current

When the air-cooled chiller works normally, the voltage is 380V (the voltage of DYJ-01A~DYJ-02A is 220V, and the voltage of other regions abroad also has 410V, etc.), and the current is normal within the range of 11A-15A;


2) Check the compressor regularly

The compressor is the "heart" of the chiller, and its quality directly affects the stability of the chiller. The necessary acceptance test for the chiller should be carried out in accordance with the principles of air tightness test first, vacuum test second, sub-item test first, and complete machine test second.


3) Regular cleaning

In addition to checking the technical performance of the chiller, it is also necessary to protect the clean appearance of the chiller and the cleanliness of the work site. When the air-cooled chiller is running for 6 months, the entire system, such as pipes, filters, condensers, fans, etc., must be cleaned, especially the fans. Like our commonly used fans, dust will affect heat dissipation, so the cooling efficiency will directly lower.


4) Check the meter regularly

The temperature control meter is out of control. Replace the temperature control meter. High pressure failure. Poor heat dissipation, too dirty radiator, bad air to clean the radiator, improve the ventilation conditions. , Replace the high-pressure engine.


5) Regularly check whether the refrigerant has decreased

Judge according to the high and low pressure gauge values on the front of the air-cooled chiller. When the chiller is operating normally, the high pressure is 11-17kg, and the low pressure is 3-5kg. In shutdown state, both high pressure and low pressure are around 0.6kg.


The high-efficiency refrigeration function of air-cooled chillers is inseparable from the daily maintenance and safety inspection of the products. Therefore, it is very important to check the operation of air-cooled chillers. In addition to the main inspections above, it is also necessary to check the oil level and oil temperature of each compressor, check the main power supply voltage and current, and check whether the set value of the chilled water supply temperature is appropriate. If there is a problem, make changes in time.




H.Stars has been a HVACR manufacturer for more than 26 years. Customized high efficient chiller / heat pump provide -50℃ to 90℃ solution to the customer. If you are interested in our air-cooled chillers, you can contact us. Email: maychow@hstars.com.cn



评论

此博客中的热门博文

Where are water-cooled chillers used? What is a chiller used for?

  Water-cooled chiller   is a cooling water device that can provide constant temperature, constant current and constant pressure. A chiller is a machine that achieves refrigeration through vapor compression or absorption cycles. These liquids can flow through heat exchangers to cool the air or equipment. The industrial chiller can always output ice water with a lower temperature than the ambient temperature. It can be used wherever cooling is required, either direct cooling or indirect heat exchange. The main components of a water-cooled chiller are compressor, condenser, evaporator, water pump, and water tank. Chillers have a wide range of applications. The chiller can be used to cool the injection mold, improve the quality of plastic products, cool the vacuum coating, control the temperature of the vacuum coating machine, cool the food industry, fast cooling processing, chemical industry, effectively control the temperature of chemicals, cooling buildings, concrete fast Cool...

Ways and solutions of noise produced by chillers - www.oumalchiller.com

  It is inevitable that the chiller will produce sound when it is working. For example, when the fan rotates, the fan blades rub against the air, it will produce sound. Normal sound is allowed. However, even the sophisticated refrigeration equipment will appear after a long period of use. Fault. Then, the editor of   Oumal Chiller   will take you to understand the causes and solutions of the noise produced by the chiller. First, find the reason from the parts that are easy to check and observe: 1. Are the anchor screws loose? The chiller is fixed on the ground. After running for a long time, the anchor bolts will be loose, and the chiller will be unstable, which will cause noise. This situation can be solved by replacing the anchor bolts, and vibration reduction can also be installed if conditions permit. The purpose is to make the chiller firmly fixed on the ground. 2. Whether the connecting pipeline is firm There are large and small pipes on the chiller, connecting the ...

How is the Refrigeration Industry Leading the Green Development with R404A

  As global environmental concerns continue to rise, the refrigeration industry is undergoing a significant transformation. Water-cooled low-temperature units exported overseas are now increasingly adopting the eco-friendly refrigerant R404A, leading the way in the industry's green development. Here's a deeper look into this trend. Why Is R404A Becoming the Preferred Refrigerant for  Water-Cooled Low-Temperature Units ? R404A is a blend of refrigerants that stands out due to its environmentally friendly properties. It is free from Ozone Depleting Potential (ODP) and has a relatively low Global Warming Potential (GWP), making it an ideal substitute for traditional refrigerants. This balance between high-performance cooling and environmental friendliness has made R404A especially popular in regions with strict environmental regulations, such as Europe and North America. Water-cooled low-temperature units exported to these areas are now commonly equipped with R404A to meet local ...