The difference between square type crossflow closed circuit cooling tower and traditional open cooling tower

H.Stars Group water cooled chiller unit always need to adopt cooling tower to supply water to the cooling system . Hence, H.Stars has summarizes the difference between square type cross flow closed circuit cooling tower and traditional open cooling tower.
The cooling water of the open cooling tower is directly contact with the air for heat exchange in the packing process, so the purity of the cooling water system cannot be maintained, and the cooling water inevitably absorbs dust and bacteria from the air. However, in the closed cooling tower, the cooling water flows in the coil, and the spray water and air are outside the disc, so the cooling water and the outside air are not in contact, and the purity of the cooling water system can be kept forever.

Advantages of square type crossflow closed circuit cooling tower
1. The cooling tower series has the advantages of high efficiency, energy saving, environmental protection, energy saving, stable operation, etc.

2. It can keep the purity of the cooling water for a long time and avoid the replacement of a large amount of cooling water. Moreover, due to the closed system, the evaporation of the cooling water and the loss of the drifting water are avoided, so that customers can save more operating water charges and it is more suitable for use in areas where water resources are inadequate.

3. Since the purity of the cooling water greatly reduces the possibility of scaling and bacterial growth in the cooling water system, the purification of the water system and the cleaning of the pipeline are reduced, which can save the customer a large daily maintenance cost.

4. Since the cooling water is not directly contact with the air, so it does not pollute the cooling water and water system. Therefore, the closed cooling tower can work in places with bad air conditions, such as dusty and smelly places.

The application industry of Square type crossflow closed circuit cooling tower
The cooling water of the cooling tower can provide the need of cooling for the production process and the machine. The industries it adapts to are:
Air conditioning equipment industry
Metal processing industry
Energy industry
Chemical industry
Plastic products industry
Pharmaceutical Industry
Video processing industry

You can visite us to learn more about the working principles of square type crossflow closed circuit cooling tower.(https://www.hstarschiller.com)
 The difference between square type crossflow closed circuit cooling tower and traditional open cooling tower

评论

此博客中的热门博文

Constant Temperature Swimming Pool Heat Pump Unit | Hstarschiller.com

  We all know that winter swimming has many advantages: 1. It can enhance cardiovascular function. 2. The stimulation of cold water can close the peripheral blood vessels, increase the blood supply of important organs such as heart, brain, liver and spleen, so that more oxygen can be delivered to brain cells in time, which is conducive to the elimination of nervous system fatigue. 3. The skin of those who insist on winter swimming is ruddy, shiny and elastic. And people also hope to enjoy the fun of swimming in winter, but not everyone can bear it.  Hstars group constant temperature swimming pool heat pump  can be a good solution. 1. Demand analysis of swimming pool with constant temperature Constant temperature swimming pool, also known as indoor constant temperature swimming pool; that is, the temperature of the water in the pool heating system is maintained at 26~28℃, which is suitable for the temperature of the human body. When the indoor swimming pool is designed, th...

The Role and Characteristics of Condenser in Refrigeration System

  The four major components of the refrigeration system are compressor, evaporator, condenser and throttling device. The role of the condenser in the refrigeration system is mainly to cool and liquefy the gaseous refrigerant in the high temperature and high pressure state discharged from the compressor, so as to meet the requirements of the circulating use of the refrigerant in the system. The selection of the temperature difference between the condensing temperature and the coolant inlet and outlet involves economic issues in the refrigeration system. Increasing the condensation temperature and reducing the temperature difference between the coolant inlet and outlet can increase the heat transfer temperature difference, reduce the required heat transfer area, and reduce the investment cost of heat exchange equipment. However, lowering the condensing temperature can reduce the power consumption of the refrigeration compressor. The greater the temperature difference between the cool...

How to build a cost-saving cold room for Peanut Storage

  Peanut storage conditions have significant effects on overall quality. With   H.Stars   standards for roof pitch, ventilation and other building standards, farmer stock peanut warehouses or cold room are the best solution. Here are some suggestions on one of the type peanut cold storage. Description of Peanut Cold Storage 1. Project details: The specific parameters of the Peanut Cold Storage are as follows: a. Cold storage size: 30m (length) × 25m (width) × 4.5m (height) b. Cold storage temperature: 10 ℃ c. Cold storage goods: peanuts without shell d: Storage capacity of cold storage: 1000Ton 2. After calculation, the chiller capacity of the cold storage is: 150kw 3. Refrigeration system description (1). This project adopts:  efficient refrigeration chilled water system . a. The main refrigeration equipment of the high-efficiency chilled liquid refrigeration system is the water cooled chiller unit. After commissioning and testing in the factory, the whole chilled c...