H.Stars Group water cooled chiller unit always need to adopt cooling tower to supply water to the cooling system . Hence, H.Stars has summarizes the difference between square type cross flow closed circuit cooling tower and traditional open cooling tower.
The cooling water of the open cooling tower is directly contact with the air for heat exchange in the packing process, so the purity of the cooling water system cannot be maintained, and the cooling water inevitably absorbs dust and bacteria from the air. However, in the closed cooling tower, the cooling water flows in the coil, and the spray water and air are outside the disc, so the cooling water and the outside air are not in contact, and the purity of the cooling water system can be kept forever.

Advantages of square type crossflow closed circuit cooling tower
1. The cooling tower series has the advantages of high efficiency, energy saving, environmental protection, energy saving, stable operation, etc.

2. It can keep the purity of the cooling water for a long time and avoid the replacement of a large amount of cooling water. Moreover, due to the closed system, the evaporation of the cooling water and the loss of the drifting water are avoided, so that customers can save more operating water charges and it is more suitable for use in areas where water resources are inadequate.

3. Since the purity of the cooling water greatly reduces the possibility of scaling and bacterial growth in the cooling water system, the purification of the water system and the cleaning of the pipeline are reduced, which can save the customer a large daily maintenance cost.

4. Since the cooling water is not directly contact with the air, so it does not pollute the cooling water and water system. Therefore, the closed cooling tower can work in places with bad air conditions, such as dusty and smelly places.

The application industry of Square type crossflow closed circuit cooling tower
The cooling water of the cooling tower can provide the need of cooling for the production process and the machine. The industries it adapts to are:
Air conditioning equipment industry
Metal processing industry
Energy industry
Chemical industry
Plastic products industry
Pharmaceutical Industry
Video processing industry

You can visite us to learn more about the working principles of square type crossflow closed circuit cooling tower.(https://www.hstarschiller.com)
 The difference between square type crossflow closed circuit cooling tower and traditional open cooling tower

评论

此博客中的热门博文

Avoid Downtime, Cut Costs: Smart Maintenance for Smarter Chillers

  Screw water-cooled chillers   typically operate around 3,000 hours per year, depending on China's climate and geographical conditions. Regular and scientific maintenance is crucial to ensure long-term, reliable operation, extend the lifespan, and reduce operating costs. Maintenance and Upkeep Preventive maintenance during operation and inspection involves creating annual and monthly maintenance plans based on actual operating conditions. Shutdown Procedures In winter, clean and dry the unit. Open the drain valve to empty the  shell-and-tube heat exchanger  to avoid freezing. The shutdown sequence is: chiller off - cooling tower fan off - cooling water pump off - chilled water pump off. Special attention to anti-freezing: 1. Drain the evaporator and condenser if the unit is outdoors below 0°C during standby. 2. Interlock the water flow switch with the unit to prevent freezing when the chilled water flow switch malfunctions. 3. Ensure water in the evaporator is flowi...

What Are the Key Requirements for Flooded-Type Heat Exchangers in Air Suspension Chillers

  Air suspension chillers   are crucial in many industrial and commercial applications, and the flooded-type heat exchanger is one of the most important components of these systems. Understanding the requirements of the heat exchanger is essential to ensuring the air suspension units operate efficiently and remain stable. A flooded-type heat exchanger works by transferring heat between two fluids with different temperatures. In air suspension chillers, it helps regulate temperature, optimize energy use, and improve overall performance. For instance, it can transfer heat from high-temperature gases to low-temperature liquids, or vice versa. 1. Material Requirements 1.1 Corrosion Resistance In many industrial environments, fluids can be corrosive. For example, they may come into contact with acidic or alkaline substances. To withstand these conditions, the heat exchanger’s tubes and casing need to be made from corrosion-resistant materials, such as stainless steel. Stainless ste...

Hotels Go Green: Heat Recovery Chillers Cut Costs and Carbon Footprints

  In the operation of hotels, energy costs are a significant factor that cannot be overlooked. The advent of   heat recovery chillers   offers an efficient and energy-saving solution for hotels. ​ A heat recovery chiller, in simple terms, not only performs cooling tasks but also effectively recovers heat. For hotels, this is a highly practical feature. Traditional chillers only accomplish cooling, wasting the heat generated. However, heat recovery chillers are different; they can convert the otherwise wasted heat into usable hot water. In principle, during the cooling cycle of a chiller, the refrigerant releases heat. Heat recovery chillers use special devices to collect this heat, and through a series of heat exchange processes, they can produce hot water. This hot water can be used in various scenarios within the hotel. For example, it can supply water for guest rooms' washing and brushing, provide hot water for the hotel's restaurant kitchen, and even be used for heati...